Close Go back Collapse all sections
Process Data set: weber OL 15 P Frost thin layer masonry mortar (weber OL 15 P Pakkasohutsaumalaasti) (en) en

Key Data Set Information
Location FI
Geographical representativeness description Nordic and Baltic countries
Reference year 2023
Name
weber OL 15 P Frost thin layer masonry mortar (weber OL 15 P Pakkasohutsaumalaasti)
Use advice for data set All processes from raw materials extraction to product transportation to the building site, assembly, as well as end of life stage and phases beyond the system boundary (A1-A5, C1-C4, D) are included in the analysis. The basic production process comprises of mixing raw materials together. Ready mixed product is then packed into small bags. At assembly phase, water is added according to instructions and it is mixed. When building is de-constructed at the end-of-life, the structure with mortar integrated into it are crushed. 90% of crushed material is recycled and used to replace natural gravel in soil construction, remaining 10% being disposed to landfill. System boundaries (cradle-to-gate with options) are illustrated in the picture below.
Technical purpose of product or process weber OL 15 P Frost thin layer masonry mortar is light-coloured, hand-applied dry mortar for thin-joint masonry in winter conditions. It is suitable for calcium silicate masonry units, Leca® Easylex partition blocks and aerated masonry units with a joint thickness of approx. 2 mm in winter conditions. The product offers low mortar consumption and compressive strength class M15. Delivered in 25 kg bags. GTIN 6415910021337.
Classification
Class name : Hierarchy level
  • EPDNorge: Construction / Technical-chemical building materials products
General comment on data set Data quality: Specific data for the product composition are provided by the manufacturer. The data represent the production of the declared product and were collected for EPD development in the year of study. Background data is based on EPDs according to EN 15804 and different LCA databases. The data quality of the raw materials in A1 is presented in the table below. Allocation: The allocation is made in accordance with the provisions of EN 15804. Incoming energy and water and waste production in-house is allocated equally among all products through mass allocation. Effects of primary production of recycled materials is allocated to the main product in which the material was used. The recycling process and transportation of the material is allocated to this analysis. Cut-off criteria: All major raw materials and all the essential energy is included. The production processes for raw materials and energy flows with very small amounts (less than 1%) are not included. These cut-off criteria do not apply for hazardous materials and substances.
Copyright Yes
Owner of data set
Quantitative reference
Reference flow(s)
Biogenic carbon content
  • Carbon content (biogenic): 0.0 kg
  • Carbon content (biogenic) - packaging: 0.014554047626 kg
Time representativeness
Data set valid until 2028
Time representativeness description "2023-09-09" - "2028-09-09"
Technological representativeness
Technology description including background system weber OL 15 P Frost thin layer masonry mortar is produced according to the requirements of SFS-EN 998-2:2016 (Designed masonry mortar (thin layer masonry mortar) for internal and external applications in structural masonry). Material consumption: see Product datasheet Recommended water content: approx. 5l/25 kg (0.20 l/kg) More information: www.fi.weber/muuraus-ja-rakennelaastit/varilliset-ja-erikoismuurauslaastit/weber-ol-15-p-pakkasohutsaumalaasti

Indicators of life cycle

IndicatorDirectionUnit Production
A1-A3
Transport
A4
Installation
A5
De-construction
C1
Transport
C2
Waste processing
C3
Disposal
C4
Recycling Potential
D
Input
  • 0.5101
  • 0.003043
  • 0.005161
  • 0.0003
  • 0.0005338
  • 0.01022
  • 0.0008082
  • -0.008163
Input
  • 0.3284
  • 0
  • -0.3284
  • 0
  • 0
  • 0
  • 0
  • 0
Input
  • 0.8385
  • 0.003043
  • -0.05955
  • 0.0003
  • 0.0005338
  • 0.01022
  • 0.0008082
  • -0.008163
Input
  • 2.684
  • 0.2417
  • 0.01902
  • 0.05507
  • 0.04241
  • 0.01985
  • 0.02257
  • -0.03679
Input
  • 0.707
  • 0
  • -0.01699
  • 0
  • 0
  • 0
  • 0
  • 0
Input
  • 3.391
  • 0.2417
  • 0.00203
  • 0.05507
  • 0.04241
  • 0.01985
  • 0.02257
  • -0.03679
Input
  • 0.002986
  • 0
  • 0.000002529
  • 0
  • 0
  • 0.00001706
  • 0.000009793
  • -0.00007048
Input
  • 0.01305
  • 0.0001064
  • 0.00007158
  • 0
  • 0.00001867
  • 0.000207
  • 0.00001677
  • -0.0001669
Input
  • 0.01516
  • 0.0003567
  • 0.0002026
  • 0
  • 0.00006258
  • -0.00001282
  • 0.00003621
  • -0.0001715
Input
  • 0.002328
  • 0.00002753
  • 0.0002178
  • 0.000002834
  • 0.000004829
  • 0.000034
  • 0.00002777
  • -0.00128
Output
  • 0.006783
  • 0.00001323
  • 0.000001106
  • 0.000001621
  • 0.000002322
  • 0.000001983
  • 0.000001589
  • -0.000008403
Output
  • 0.1366
  • 0.02103
  • 0.005059
  • 0.00006521
  • 0.003689
  • 0.00006263
  • 0.1001
  • -0.0002548
Output
  • 0.00000887
  • 0.00000165
  • 1.87E-7
  • 3.824E-7
  • 2.895E-7
  • 2.099E-7
  • 1.469E-7
  • -2.765E-7
Output
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
Output
  • 0.0005464
  • 0
  • 0.003916
  • 0
  • 0
  • 0.9
  • 0.000008924
  • -0.000001651
Output
  • 0.0003009
  • 0
  • 0.0002523
  • 0
  • 0
  • 0.000002072
  • 1.682E-7
  • -0.00006171
Output
  • 0.006496
  • 0
  • 0.0006397
  • 0
  • 0
  • 0.000003553
  • 0.00001388
  • -0.0000149
Output
  • 0.1
  • 0
  • 0.009678
  • 0
  • 0
  • 0.00005375
  • 0.0002099
  • -0.0002254

IndicatorUnit Production
A1-A3
Transport
A4
Installation
A5
De-construction
C1
Transport
C2
Waste processing
C3
Disposal
C4
Recycling Potential
D
Abiotic depletion potential - fossil resources (ADPF)
  • 4.68
  • 0.2417
  • 0.01844
  • 0.05507
  • 0.04241
  • 0.01985
  • 0.02257
  • -0.03486
Abiotic depletion potential - non-fossil resources (ADPE)
  • 0.000003696
  • 2.654E-7
  • 8.196E-9
  • 6.14E-9
  • 4.656E-8
  • 8.109E-9
  • 7.388E-9
  • -1.83E-7
Acidification potential, Accumulated Exceedance (AP)
  • 0.002396
  • 0.00006533
  • 0.000003253
  • 0.00004186
  • 0.00001146
  • 0.000005173
  • 0.000007296
  • -0.00001855
Global Warming Potential - biogenic (GWP-biogenic)
  • -0.03679
  • 0.000006378
  • 0.0366
  • 7.502E-7
  • 0.000001119
  • 0.000005521
  • 9.577E-7
  • -0.00004111
Global Warming Potential - fossil fuels (GWP-fossil)
  • 0.4997
  • 0.01554
  • 0.0007127
  • 0.004
  • 0.002726
  • 0.000639
  • 0.0008204
  • -0.00206
Global Warming Potential - total (GWP-total)
  • 0.4639
  • 0.01555
  • 0.03732
  • 0.004
  • 0.002728
  • 0.000648
  • 0.0008215
  • -0.002103
Global Warming Potential - land use and land use change (GWP-luluc)
  • 0.000149
  • 0.000004537
  • 0.000005937
  • 3.154E-7
  • 7.96E-7
  • 8.843E-7
  • 2.016E-7
  • -0.000001393
  • 0.465
  • 0.01555
  • 0.000773
  • 0.004
  • 0.002728
  • 0
  • 0
  • -0.002204
Eutrophication potential - freshwater (EP-freshwater)
  • 0.00006466
  • 1.185E-7
  • 2.958E-8
  • 1.457E-8
  • 2.079E-8
  • 4.038E-8
  • 9.297E-9
  • -5.477E-8
Eutrophication potential - marine (EP-marine)
  • 0.0006075
  • 0.00001964
  • 6.503E-7
  • 0.00001848
  • 0.000003446
  • 0.000001516
  • 0.000002711
  • -0.000006433
Eutrophication potential - terrestrial (EP-terrestrial)
  • 0.004669
  • 0.0002172
  • 0.000007474
  • 0.0002
  • 0.00003811
  • 0.00001746
  • 0.00002991
  • -0.00007559
Photochemical Ozone Creation Potential (POCP)
  • 0.001544
  • 0.00006985
  • 0.00000199
  • 0.00005574
  • 0.00001225
  • 0.000004676
  • 0.000008564
  • -0.00001995
Depletion potential of the stratospheric ozone layer (ODP)
  • 2.443E-8
  • 3.591E-9
  • 9.7E-11
  • 8.64E-10
  • 6.3E-10
  • 1.27E-10
  • 3.1E-10
  • -3.75E-10
Water (user) deprivation potential (WDP)
  • 5.817
  • 0.1854
  • 0.9122
  • 0.0117
  • 0.03253
  • 2.19
  • 0.1392
  • -1.635

IndicatorUnit Production
A1-A3
Transport
A4
Installation
A5
De-construction
C1
Transport
C2
Waste processing
C3
Disposal
C4
Recycling Potential
D
1This impact category deals mainly with the eventual impact of low dose ionizing radiation on human health of the nuclear fuel cycle. It does not consider effects due to possible nuclear accidents, occupational exposure nor due to radioactive waste disposal in underground facilities. Potential ionizing radiation from the soil, from radon and from some construction materials is also not measured by this indicator.
2The results of this environmental impact indicator shall be used with care as the uncertainties on these results are high or as there is limited experiences with the indicator.
Potential Human exposure efficiency relative to U235 (IRP) 1
  • 1.148
  • 0.001056
  • 0.0004072
  • 0.00024
  • 0.0001853
  • 0.000333
  • 0.000103
  • -0.0003199
Potential incidence of disease due to PM emissions (PM) 2
  • 1.287E-8
  • 1.368E-9
  • 2.1E-11
  • 5.066E-9
  • 2.4E-10
  • 8.2E-11
  • 1.55E-10
  • -3.95E-10
Potential Soil quality index (SQP) 2
  • 2.677
  • 0.2773
  • 0.01103
  • 0.00669
  • 0.04865
  • 0.01122
  • 0.0869
  • 0.07912
Potential Comparative Toxic Unit for humans - non-cancer effects (HTP-nc) 2
  • 3.879E-9
  • 1.71E-10
  • 1.4E-11
  • 2.8E-11
  • 3E-11
  • 1.2E-11
  • 8E-12
  • -4.5E-11
Potential Comparative Toxic Unit for humans - cancer effects (HTP-c) 2
  • 1.95E-10
  • 0
  • 0
  • 1E-12
  • 0
  • 0
  • 0
  • -2E-12
Potential Comparative Toxic Unit for ecosystems (ETP-fw) 2
  • 4.19
  • 0.1768
  • 0.0141
  • 0.0301
  • 0.03101
  • 0.01407
  • 0.01232
  • -0.03589